Features
Applications
■
■
■
■
■
■
Lead free as standard
RoHS compliant*
ESD protection
Protects 2 lines
Low clamping voltage
Bidirectional configuration
■
■
■
■
T1/E1 line cards
ISDN telecom equipment
XDSL, USB, SCSI & ethernet interfaces
Data & bus lines for FCC Part 68
applications
CDWBS16-PLC01-6 TVS Diode Array
General Information
The CDWBS16-PLC01-6 device provides protection for the external ports of
telecom equipment such as cellular base stations, XDSL, USB, SCSI &
16
15
14
13
12
11
10
9
Ethernet interfaces and data lines for FCC Part 68 applications.
Protection provided by the devices meets the IEC 61000-4-2 (ESD), 61000-4-4
(EFT) and 61000-4-5 (Surge) standards. The device measures 10.15 mm x 10
mm and is intended to be mounted directly onto an FR4 printed circuit board.
1
2
3
4
5
6
7
8
Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted)
Parameter
Symbol
Minimum
Nominal
Maximum
Unit
Capacitance @ 0 V, 1 MHz
Rated Standoff Voltage
Breakdown Voltage @ 1 mA
Clamping Voltage @ I P = 100 A 1
C
V WM
V BR
V C
8
50
6
15
pF
V
V
V
Clamping Voltage @ I P = 200 A
Leakage Current @ V WM
2
V C
I D
16
25
V
μA
ESD Protection: IEC 61000-4-2
Contact Discharge
Air Discharge
EFT Protection: IEC 61000-4-4 @ 5/50 ns
Surge Protection: IEC 61000-4-5 @ 8/20 μs
Level 2 (Line-Gnd) & Level 3 (Line-Line)
Notes:
1. V C tested at 10/1000 μs impulse waveform.
2. 10/160 μs impulse waveform per FCC Part 68.
Thermal Characteristics (@ TA = 25 °C Unless Otherwise Noted)
±8
±15
40
24
kV
kV
A
A
Parameter
Peak Pulse Power (td = 10/1000 μs)
Operating Temperature Range
Storage Temperature Range
Symbol
P PP
T J
T STG
Min.
-55
-55
Nom.
25
25
Max.
1500
+150
+150
Unit
W
°C
°C
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex